NOTE
NOTE
The audio oscillator and voltmeter used in
Cable requirements are identified in figure
the  following  procedures  are  Hewlett-
6-10.
Packard Models 204C (option 25) and 403B
2.  If testing is performed in a shop area,
(option 001), respectively, configured as
connect multiplexer set to a source meeting the power
part of the Hewlett-Packard Model 3550B
requirements specified in table 1-1.
portable test set. Equivalent items may be
substituted. Voice channel input/output
3.
Set POWER CONTROL switch to ON.
impedance is 600 ohms (balanced).
4.
Momentarily
press
DISPLAY
RESET
7.  Set audio oscillator output frequency to
switch.
1000 Hz +5 percent.
5.  Observe that POWER CONTROL ON
8.
Set audio oscillator output level to -16 +0.1
indicator is lighted and the following indicators are out:
dBm.
LOSS OF MUX TIMING
9.  Measure audio voltage amplitude appearing
at the channel's demultiplexer output. Amplitude should
LOSS OF DEMUX TIMING
be +7 +0.1 dBm.
LOSS OF FRAME A
10. Repeat steps 6 through 9 for each voice
channel being tested.
LOSS OF FRAME B
11. Set POWER CONTROL switch to OFF and
LINK ERROR RATE
disconnect all test setup cables.
POWER SUPPLY
6-42.  BIT COUNT INTEGRITY TEST. Perform digital
channel bit count integrity (BCI) test as follows:
TEMPERATURE
NOTE
MULTIPLEXER CARD
Testing of the BCI requires that the
DEMULTIPLEXER CARD
multiplexer set be set up in a full duplex
configuration. Refer to chapter 3 for setup
NOTE
instructions.
At very low multiplexer output rates
1.  Connect cables between multiplexer MUX
(Ro),  the  time  for  initial  frame
DATA OUT and demultiplexer DEMUX DATA IN
synchronization by the demultiplexer
connectors, and between multiplexer MUX TIMING OUT
may approach 6 minutes. Also, it may
and demultiplexer DEMUX TIMING IN connectors (figure
be necessary to momentarily press the
DISPLAY RESET switch to extinguish
the  LOSS  OF  FRAME  B  indicator
following initial frame acquisition by the
demultiplexer.
6-40