3.  Determine if the frequency measured in
NOTE
step 2 is within plus or minus one part in 107 of the
oscillator's specified output frequency. If the measured
To ensure proper calibration, allow the
frequency is within this tolerance, proceed to step 5. If
frequency  counter  to  warm  up  for
the measured frequency exceeds this tolerance, proceed
approximately 15 minutes before making
to step 4.
frequency measurements.
NOTE
1.  Loosen and remove printed circuit access
cover (figure 6-2) located at front of chassis.
When the nominal specified frequency of
the installed oscillator is 9.8304 MHz, the
NOTE
acceptable tolerance is
6
+9.8304 x 10 or approximately Hz.
Steps 2 through 4 are applicable only
7
10
when the multiplexer is operating from an
internally generated reference timing signal
4.  Using a standard screwdriver,
remove
If the multiplexer is
protective cover from RT card reference timing oscillator
operating from a station clock or other
adjustment control (figure 6-8).  Using an electronic
external reference timing signal, proceed to
tuning tool, slowly rotate oscillator adjustment control
step 5.
until frequency measured at TP-10 of RT card is within
the tolerance established in step 3. Replace protective
2
Connect frequency counter to test point TP-
cover.
10 of RT card (figure 6-8) and measure output frequency
of reference timing oscillator Y1.
5.  Connect frequency counter to TP15 of RT
card (figure 6-8) and measure frequency of transition
NOTE
encoding signal.
The multiplexer set is initially delivered with a
6
Determine that the frequency measured in
reference timing oscillator whose nominal output
step 5 is 4800 +0.24 Hz.
frequency is 9.8304 MHz. For certain applications,
oscillators of different frequencies may be installed.
7
.If  the  measured  frequency  is  within
If  the  frequency  measured  at  TP-10  is  not
tolerance, proceed to step 8. If the measured frequency
approximately 9.8304 MHz, determine the specified
is not within tolerance, set POWER CONTROL switch to
nominal frequency of the installed oscillator before
OFF and replace RT card as prescribed in paragraph 6-
proceeding.
22. Set POWER CONTROL switch to ON and repeat
steps 5 through 7.
8.  Install and tighten printed circuit card
access cover.
6-34