Click here to make tpub.com your Home Page

Page Title: Table 5-5. List of ROM Outputs (Stuff Codes)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

T.O. 31W2-2GSC24-2
TM 11-5805-688-14-1
NAVELEX 0967-LP-545-3010
Table 5-5. List of ROM Outputs (Stuff Codes)
DATA WORD (BIT 0 POSITION)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
WORD
WC0
1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 01
COUNT
INPUTS:
WC1
0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
WC3
0001111000011110000111100001111
WC4
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
STUFF
CODE
OUTPUTS:
PSC
Y1, Y4
1 1 0 0 1 1 1 0 1 0 11 1 1 1 1 0 1 1 0 1 0 1
NSC
Y2, Y5
1 1 0 0 0 0 0 1 0 1 0 1 1 1 0 0 1 0 1 1 0 1 0
NAC
Y3, Y6
0 0 1 1 0 0 0 0 1 0 1 0 0 0 1 1 0 1 0 1 0 1 0
5-335. Word 29 signal MW29 and end of-scan signal
that is receiving overhead service in the minor frame
MEOS2B enable AND gate U4-3 to produce the minor
being addressed at any given time.
frame transition signal MFT.  Signal MFT clocks the
minor frame counter consisting of flip-flop U5 and binary
5-337. Gated Clock Generation Function.
counter U6. The minor frame counter is incremented by
signal MFT until the frame count 31. Signal MMF31, the
5-338.  Channel address signals MCHADO through
terminal count from U6, is generated by the binary
MCHAD8 from the sequencer card contain the address
counter. Signal MFC1 is applied to minor frame activity
of the active channel selected to receive a gated clock
detector U1-6 in the composite error detector circuits for
signal. The channel address signals are applied at the
diagnostic purposes.  Multiplexer minor frame count
multiplexer clock rate (MRIO) to the inputs of overhead
signals MMFCO through MMFC4 are routed to the seq
register No.  1 (U48) and to the C input of address
card.  Minor frame terminal count signals MMF31A-,
selector U53. In normal operation, AND gate U12-6 in
MMF31B-, and MMF31Care distributed to channel card
the gated clock control circuit is inhibited by the absence
locations Al through A15 for use by the RCB cards.
of MPSE. This condition sets flip-flop U11 in the gated
clock add control circuit to generate an enable signal to
5-336. Minor frame count signals MFCO through MFC4
the C input of U53.
from minor frame counter U5, U6 are applied to
overhead data multiplexer U50 to identify the used port
5-89

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business