detected.
The TEMPERATURE indicator  in the
when an overheating condition occurs in the power
ALARMS  group  lights  when  an  overtemperature
supply. When the signal is applied to the thermal control
condition is detected in the power supply.
Three
circuit inhibit power supply signal IPSE is generated to
switches in the TEST CONTROL group and the POWER
turn off the power supply. At the same time, the thermal
CONTROL switch are also mounted on the front panel.
control circuit generates a lamp enable signal that lights
the TEMPERATURE indicator on the front panel and
5-156. When the POWER CONTROL switch is set to
generates remote temperature signals (TEMPC1/C2)
ON, ac power is applied to the power supply and to the
that are applied to the rear panel.
blower fan in the multiplexer set.
The POWER
CONTROL ON indicator lights when the power supply is
5-160. When the LAMP TEST switch is pressed during
on. The incoming ac power is applied through a circuit
normal operation, all the indicators on the front panel
breaker and the POWER CONTROL switch.
light.  The lamp test function does not affect the
operation of the functional circuits in the multiplexer set.
5-157. High-level signals LDCRD, LMOOT, LMCDR,
When the LAMP TEST switch is pressed, lamp test
LDTIM, and LMTIM are the enable signals from the
signal LT is generated and the signal initiates the
display card that light the DEMULTIPLEXER CARD,
following functions:
MULTIPLEXER OUT OF TOL, MULTIPLEXER CARD,
LOSS OF DEMUX TIMING, and LOSS OF MUX TIMING
a.
The POWER SUPPLY indicator lights.
indicators on the front panel as shown in figure 5-10.
The LOSS OF FRAME A and LOSS OF FRAME B
b.  The  thermal
control
circuit
lights
the
indicators are enabled by signals LLOFA and LLOFB
TEMPERATURE indicator.
from the ERD card. The LINK ERROR RATE indicator is
enabled by signal LLER from the ERD card. The error
c.  The two 7-segment decoder/ drivers enable
conditions that the indicators represent are listed in table
the FAULT LOCATION numerical display to show 88.
4-1.
d.  The display card generates indicator enable
5-158. The card location of a faulty card is presented on
signals that light the LOSS OF MUX TIMING, LOSS OF
the FAULT LOCATION numerical display on the front
DEMUX
TIMING,
MULTIPLEXER
CARD,
panel. The card address for the faulty card is contained
MULTIPLEXER OUT OF TOL, and DEMULTIPLEXER
in signals TA0 and TA1 that contain the tens count 0, 1,
CARD indicators.
or 2, and signals UAO, UA1, UA2, and UA3 that contain
the units digit that is between 0 and 9. The incoming
e.  The ERD card generates indicator enable
card address signals from the display card are applied to
signals that light the LOSS OF FRAME A, LOSS OF
7-segment decoder/driver logic circuits, which produce
FRAME B, and LINK ERROR RATE indicators.
the outputs that enable the appropriate numerical
readout from the units and tens numerical display.
When the LAMP TEST switch is released, all indicators
(except the POWER CONTROL ON indicator) return to
5-159. Overtemperature signal HOT-generated and
their normal off state, assuming that the multiplexer set
applied to the thermal control circuit on the front panel
is in a no-error condition.
5-36