Item 26. Stability Augmentation System (SAS), Single SAS Operation (Continued)
RATINGS
PROCEDURE
GREEN
AMBER
RED
for SAS amplifier 1 14E3030-47 and
-49, meter indicates between 150
and 350 in the direction indicated by
the L-R switch and then decreases
to one half the maximum indication
in approximately 7 seconds and
holds steady.
Item 27. Stability Augmentation System (SAS), Dual SAS Operation
RATINGS
PROCEDURE
GREEN
AMBER
RED
Set FLT CONT panel SAS switch to
Meter indications for DC and AC are
Meter readings are erratic and incorrect.
both ON and perform test procedures
the same as for single SAS
given in item 26 for each SAS
operation. Meter indications for
amplifier
PITCH, ROLL, YAW, and S/SLIP
are one-half (* one scale division) of
the values recorded in item 26.
SAS OFF caution light comes on for
the inoperative amplifier.
25
Change 2
TM 11-1'520-209-ESC
|