26
TM 11-1520-209-ESC
Item 28. Speed Trim Facility
RATINGS
PROCEDURE
GREEN
AMBER
RED
Set the speed trim amplifier selector
With selector switch at AC and B+,
Meter readings are erratic and incorrect
switch to AC, B+, and MAN; for each
meter indicates between 0.7 and
switch position set, observe meter
0.9. At MAN, meter indicates
indications. Set selector switch to
between 0.5 and 0.9 for maximum
A/S, FWD, and AFT and, in turn,
forward trim wheel position, 0.0 to
press the PRESS TO TEST switch in
0.1 for maximum aft position, and
each switch position. Observe meter
0.3 to 0.4 for 0 position. At FWD
indications.
and AFT, meter indicates 0; press
the PRESS TO TEST switch, meter
indicates approximately 0.5. For
speed trim amplifier 114E2186-23
or 114E218626, with selector switch
at AS, meter indicates a maximum
of 0.1. Press the PRESS TO TEST
switch; meter indicates greater than
0.1. For speed trim amplifier
114E2186 30, with selector switch
at AS, meter indicates a maximum
of 0.3. Press the
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |