24
TM 11-1520-209-ESC
Item 26. Stability Augmentation System (SAS). Single SAS Operation (Continued)
RATINGS
PROCEDURE
GREEN
AMBER
RED
L-R switch alternately to L and R at
lector switch at PITCH, ROLL and
each switch position and observe
S/SLIP during L-R switch operation
meter indication.
meter pointer moves slowly to a
value between I50 and 350. For
SAS amplifiers 114E3030-40.
114E3030-42. and 114E3030-43.
meter pointer remains at that
position. For SAS amplifiers 1
14E3030-47 and I 14E3030-49.
meter pointer slowly returns to 0O.
(Record the maximum indication for
use in item 27 ) With selector switch
at YAW for SAS amplifiers
114E3030-40, -42, and -43. meter
pointer moves in the direction
indicated by the position of the L-R
switch Indication then decreases to
one-third of the original indication
within 3 to 7 seconds. With the
selector switch at YAW
|