(h) After each hole is drilled, install bolt, washer and nut to insure air cleaner
dues not shift during subsequent drilling operation (view B).
(i) After drilling all four 5/8 inch holes, loosen all mounting bolts and check for
g a p between air cleaner base plate and outriggers. If a gap exists, use
washers (maximum of three per bolt) to shim gap lighten 5/8 inch mounting.
(j) Apply primer, NSN 8030-00-900-2373 and locking compound. NSN 8030-00-
148-9833, to bolt threads and nuts.
(k) Tighten 5/8 inch bolts to 85-95 1b-ft (115-129) and 3/8 inch bolts to 22-30 lb-
ft (30-41 Nm).
(l) Tighten fender extension mounting bolts.
(m) Connect battery ground cables (TM-20).
4-6. V-Band Clamps (Fig. 4-11)
Figure 4-11.
V-band clamps.