Click here to make tpub.com your Home Page

Page Title: Section I. GENERAL
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TB 9-1430-1533-40-1
Section I. GENERAL
improvement, let us know. Send us an EIR. You, the
1. Purpose and Scope. The purpose of this purging
user, are the only one who can tell us what you don't like
process is to eliminate excessive HIPIR downtime
about your equipment. Let us know why you don't like
caused by contamination and leakage of the coolant
the design. Tell us why the procedure is hard to perform.
system. This procedure informs and guides personnel
Put it on an SF 368 (Quality Deficiency Report). Mail it to
responsible for direct and general support maintenance
the address stated in DA PAM 738-750. We will send
of Radar Set AN/MPQ-57, High-Powered Illuminator
you a reply.
Radar (HIPIR). These instructions contain maintenance
information beyond the scope of the tools, equipment or
3. Description.
supplies normally available to using organizations.
Information in this bulletin is supplemental to and used in
conjunction with TM 9-1430-1533-12-1.  This bulletin
DESCRIPTION OF THE CLEANING STATION
also contains general maintenance and unique removal,
installation, repair, and purging operations peculiar to
The Cleaning Station (fig. 1) contains five reservoirs (6.5
direct  and  general  support.
Maintenance  test
gals each), four heater elements (1.5 KW each for
procedures for units of this equipment are covered in TM
heating reservoirs Nos. 1, 2 and 3), a thermometer, and
9-1430-1533-34-1.
a 1.75 V 650 MA DC power supply. Additional items are:
A pump (maximum pressure 100 PSI), a filter housing
NOTE
with elements, and a pressure indicator. The reservoirs
are filled as follows:
MWO 9-1430-1533-50-3 (Replacement
No.  1 with a (ETHYLENE DIAMINE TETRA ACETIC
of Cooling Hoses) appendix A and MI-
ACID) Versene-Acid solution, No. 2 with an alkali-free
B0162R1 (Coolant Hoses "O" ring
soap solution, No. 3 with a pyrosulphate solution. No. 4
change) appendix B must be applied
with distilled or demineralized water, and No.  5 with
before  the  purging  procedure  is
ethylene glycol.
performed.
4. General Instructions. None.
2. Reporting Equipment Improvement Recom-
mendations (EIRs). If your equipment needs
Figure 1. Cleaning station.
5

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business