TM 5-3610-254-14
Table 5-1. DIRECT SUPPORT TROUBLESHOOTING (cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 3.
Inspect for correct electrical connection at BLACKOUT WARNING switch as follows:
a.
Remove three nuts, lockwashers, and bolts that secure the cover to the housing. Loosen
the fourth nut and allow the cover to swing down.
b.
Using a suitable meter or test light, check for continuity at wire connections when
blackout warning switch is activated. If necessary, replace defective switch as described
3. UNABLE TO MAKE TELEPHONE CONNECTION WITH OTHER UNITS OF THE SPECIAL WARFARE PRINTING
PLANT
Inspect for one or more defective telephone binding posts.
If necessary, repair or replace defective binding posts as described in paragraph 5-25.
4. NO ELECTRICAL POWER TO SHELTER SYSTEM
Step 1.
Inspect for generator set power source not operating.
Start the generator set in accordance with the applicable Department of the Army Technical
Manual.
Step 2.
Inspect for circuit breakers not positioned to ON.
Position applicable circuit breakers to ON.
Step 3.
Check that main power cable is correctly connected at main power receptacle.
5-4