2-7 COMPARTMENT CONTROL MODULE (CONT).
LOCATION
ITEM
ACTION
Nonmetallic tubing
Replace tubing if torn or broken (item 2,
Fabricate replacement tubing (3) (item 2,
as tubing being replaced.
INSTALLATION
1. Install loop clamp (9) on tube (7) if removed.
2. Install hose clamps (3 and 4) on tubes
(7 and 8) if removed.
3. Position pressure switch S6 (5) between tubing
(7 and 8) with switch terminals pointing away
from the thermal flasher DS12 (10) and low
and high markings toward the front panel (11).
4. Install tube (7) on low side of switch and tube
(8) on high side.
5. Slide hose clamps (3 and 4) over tube
connections. Install electrical connectors (6).
Refer to wiring diagram (p. 2-99).
6. Install washer (2) and screw (1).
7. Reassemble CCM (p. 2-77).
2-78
|