5. FUEL FAILS TO IGNITE.
Step 1. Check for excessively worn or defective breaker points in the combustor
magneto(1).
Replace breaker points (para 2-46).
Step 2. Check for defective ignition cable. See WATER HEATER DOES NOT HEAT
WATER, step 3.
Replace defective ignition cable (para 2-53).
6. WATER HEATER SHUTS DOWN DURING OPERATION.
Step 1. Check for defective thermostatic switch S1. See WATER HEATER DOES NOT
HEAT WATER, step 2.
Replace thermostatic switch S1. See paragraph 2-33.
Step 2. Check for defective wiring. Follow procedures of FUEL PUMP AND IGNITION
DRIVE MOTOR WILL NOT START WITH HEATER CONTROL SWITCH IN HEATER
ON POSITION.
Replace wiring (para 2-44).