2-148
2-33. LIQUID FUEL WATER HEATER AND CABINET TOP COVER.
This task covers:
c. Reassembly
a. Disassembly
b. Repair
INITIAL SETUP
References
Tools and Special Tools
FM 10-16
Automotive Maintenance and Repair Field Maintenance
TM 43-0139
Shop Equipment, Basic, Less Power (SC 4910-95-CL-A31)
Automotive Maintenance and Repair Shop Equipment:
Personnel Required
Organizational Maintenance Common No. 1, Less Power
2
(Sc 4910-95-CL-A74)
Equipment Condition
Materials/Parts
Unit maintenance authorized components are removed in
Polyurethane coating (black) (item 28, app C)
TM 3-4230-209-20&P and are not covered in this manual.
Polyurethane coating (green) (item 29, app C)
Pressure sensitive tape (item 41, app C)
REMARKS
ACTION
LOCATION/lTEM
Liquid Fuel Water Heater and
Cabinet Top Cover/
Loosen the two clamping catches (1) holding the cabinet top cover (2)
Clamping catch (1)
down. Cut or drill two solid rivets (3) from each clamping catch (1) only if
Cabinet top cover (2)
Solid rivet (3)
defective. Remove and discard clamping catches (1).
Decal (4)
Scrape decal (4) from underside of cabinet top cover (2) if damaged or
illegible.
Plate (5)
Scrape off operating instruction plates (5 and 6) if damaged or illegible.
Plate (6)

Privacy Statement - Press Release - Copyright Information. - Contact Us