TM 11-6625-937-12
1-10. Differences In Models
Indicator, Channel Alignment ID-1189 (XE-2)/PR differs from ID-1189/PR models as follows:
a. Adapter, Connector U-389(XE-1)/PR is included in the ID-1189(XE-2)/PR only for testing Battery, Dry BA-4534/U.
An additional indicating scale on the meter is used for showing the condition of this battery.
b. Adapter, Receiving Set MX-851i-XE-4)/PR is included in the ID-1189(XE-2)/PR only for aligning Receiving Set,
Radio AN/PRR-9 (XE-9).
c. The safety switch and safety switch actuator are not installed in the ID-1189(XE-2)/PR or in later models of
the ID-1189/PR.
d. The internal battery connector is located on the surface of the top plate assembly of the ID-1189(XE-2)/ PR and
later models of the ID-1189/PR.
e. The ID-1189(XE-2)/PR only contains an instruction plate that covers procedures for aligning the AN/PRR-9 (XE-9)
and testing Battery BA-4534/U.
f. Provision has been made in the lid in the ID-1189(XE-2)/PR only for the storage of Adapter, Connector U-389(XE-
1)/PR and Adapter, Receiving Set MX-8512(XE-1)/PR.
g. Both models of the equipment can be used to align the AN/PRR-9 and AN/PRT-4 or test the BA-399/U and BA-
505/U. The ID-1189 (XE-2) /PR only can be used to align the AN/ PRR-9(XE-9) or test the BA-4534/U.
Change 3 1-4
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |