TM 5-4930-233-14
TM 4930-14/1
LUBE TANK ASSEMBLY
5-18. LOW PRESSURE PUMP (Cont.)
b.
Repair
WARNING
Clean all parts in a well ventilated area. Avoid inhaling solvent fumes and prolonged exposure of
the skin to cleaning solvent. Failure to do so can cause severe injury or death. Do not use near
flame or excessive heat. Flash point of solvent is 100 to 138 (38 to 59 ).
F
F
C
C
(1)
Clean all parts with dry cleaning solvent.
(2)
Discard and replace all gaskets and packings.
(3)
Inspect and replace any worn or damaged parts.
(4)
Inspect threaded surfaces for damage. Replace if defective.
(5)
Inspect pump rods and tubes for cracks, breaks or other defects which would prevent proper operation.
(6) Inspect valve and valve seats for damage or wear. Replace as required.
5-95
|