TM 5-4930-233-14
TM 4930-14/1
SKID SUB ASSEMBLY
5-5. TRANSFER PUMP - REPAIR/ADJUST (Cont.)
e. Adjustment
NOTE
This adjustment can also be made to correct leaking that occurs around packing adjustment slot
(1) Run pump for approximately 5 minutes to allow teflon packings to form evenly.
(2) Allow cylinder and plunger to cool.
(3) Apply a maximum of 30 psi air pressure. If pump does not start or if leakage occurs, adjustment is required.
(4) Loosen adapter (21) to a point where its holes line up with a hole on bushing (23).
CAUTION
Do not overtighten bushing as this will cause piston assembly to bind. If pump did not operate
during run-in, skip steps (5) and (6).
(5) Place a rod through holes and hand tighten to drive bushing assembly into pump casting, thereby tightening
packings.
(6) Remove rod and repeat run-in. If pump doesn't operate proceed. If pump operates without leakage, go to
step (9).
5-22
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |