TM 5-4930-233-14
TM 4930-14/1
Table 5-1. Direct Support Troubleshooting - Continued
ITEM
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
LEAKAGE OCCURS FROM OUTLET FITTING BODY
Check preformed packings at outlet fitting body for wear.
Replace preformed packings (paragraph 5-7).
5.
LEAKAGE OCCURS AROUND FACE DIAL
Check packing and leather washer for wear at gear and shaft.
Replace packing and leather washer (paragraph 5-7).
ENGINE OIL DISPENSER
1.
LUBRICANT LEAKS FROM AROUND INLET
Check preformed packings and block "V" packing at inlet for wear.
Replace preformed packings and block "V" packing (paragraph 5-8).
2.
LUBRICANT FLOWS OUT OF NOZZLE CONTINUOUSLY
Check valve assembly and seat at lever assembly for wear.
Replace valve assembly and seat (paragraph 5-8).
3.
LEAKAGE OCCURS FROM LEVER ASSEMBLY
Check preformed packings at lever assembly for wear.
Replace preformed packings (paragraph 5-8).
4.
LEAKAGE OCCURS FROM OUTLET FITTING BODY
Check preformed packings at outlet fitting body for wear.
Replace preformed packings (paragraph 5-8).
5.
LEAKAGE OCCURS AROUND FACE DIAL
Inspect packing and leather washer for wear at gear and shaft.
Replace packing and leather washer (paragraph 5-8).
5-3
|