LUBE AND PNEUMATIC PIPING
4-45. PNEUMATIC PIPING - REPLACE/REPAIR - (Cont)
b. Repair
WARNING
Clean all parts in a well ventilated area. Avoid inhaling solvent fumes and prolonged exposure of
the skin to cleaning solvent. Failure to do so can cause severe injury or death. Do not use near
flame or excessive heat. Flash point of solvent is 100 to 138 (38 to 59 ).
F
F
C
C
(1)
Clean all hoses with a cloth dampened lightly in dry cleaning solvent.
(2)
Inspect hoses for cracks, frayed or abraded coverings or deteriorated rubber.
Inspect hose fittings for
damaged threads.
(3)
If necessary to replace any hoses or hose fittings, loosen damp (10) and remove along with fitting (11) from
hose (12).
(4)
Replace damaged item and install clamp (10) and fitting (11) onto hose (12).