TM 10-4930-233-14
TM 4930-14/1
LUBE AND PNEUMATIC PIPING
4-44. LUBE PIPING - REPLACE/REPAIR - (Cont.)
b. Repair
WARNING
Clean all parts in a well ventilated area. Avoid inhaling solvent fumes and prolonged exposure of
the skin to cleaning solvent. Failure to do so can cause severe injury or death. Do not use near
flame or excessive heat. Flash point of solvent is 100 to 138 (38 to 59 ).
F
F
C
C
(1)
Clean lube hoses with a cloth dampened lightly in dry cleaning solvent.
(2)
Inspect hoses for cracks, frayed or abraded coverings or deteriorated rubber.
Inspect hose fittings for
damaged threads.
(3)
If necessary to replace any hose or hose fitting, loosen and slide nut (8) up hose (9). Remove fitting (10) and
nut.
(4)
Replace damaged item and install nut (8) and fitting (10) onto hose (9).
c. Installation
(1)
Wrap all threads with tape.
(2)
Install tees, bushings and elbows (7) as required.
(3)
Install hose or tube (6).
(4)
Install clamps (5) with screws (4), lockwashers (3) and nuts (2).
4-130
|