TM 5-4930-233-14
TM 4930-14/1
LUBE TANK ASSEMBLY
4-38. LUBE TANK - REPLACE/REPAIR - (Cont.)
c. Repair
WARINING
Clean all parts in a well ventilated area. Avoid inhaling solvent fumes and prolonged exposure of
the skin to cleaning solvent. Failure to do so can cause severe injury or death. Do not use near
flame or excessive heat. Flash point of solvent is 100 to 138 (38 to 59 ).
F
F
C
C
(1)
Flush out each of three lubricant compartments in the tank using dry cleaning solvent.
(2)
Inspect tank for cracks defective manhole hinges, broken weldments and other damage. Replace defective
tanks.
(3)
Inspect manhole for damage, corrosion, gasket damage or wear or other conditions that could impair its sealing
ability. Replace parts as required.
4-112
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |