TM 5-4930-233-14
TM 4930-14/1
REEL CABINET ASSEMBLY
4-18. BATTERY BOX ASSEMBLY - SERVICE/REPLACE/REPAIR - (Cont.)
(10) If battery specific gravity is not adequate, remove battery from vehicle (para 4-18b) and charge. While
charging check battery specific gravity every 30 minutes. The batteries are fully charged when you get a
constant reading for three 30-minute intervals.
(11) During charging, check the electrolyte level frequently. Add distilled water when necessary.
NOTE
Batteries should be charged at least once a month while in storage. (12) If a
battery fails to take or hold a charge, replace.