TM 5-4930-233-14
TM 4930-14/1
e.
Dispensing General Purpose Grease
1.
Prepare the high pressure lubrication pump (center pump) for operation (paragraph 2-5 d).
2.
Release the hose reel lock (17) from one of the general purpose grease reels (second or fourth reel) and pull
out the required length of hose.
3.
Select the proper adapter from the reel cabinet stowage drawers (paragraph 2-6) and connect it to the grease
control valve (18).
4.
Clean each grease fitting of the part being lubricated or you may force dirt into the bearing point. If
necessary, replace a worn or damaged fitting from on board stock (stowed in reel cabinet). Attach the
adapter to the fitting and squeeze the grease control valve (18) trigger.
5.
When adequate lubricant is provided disconnect the adapter and go on to the next fitting.
6.
When lubricating is complete, disconnect the adapter from the dispenser. Wipe it clean and return it to the
equipment drawer. Rewind the hose on the reel and replace the dispenser on the bracket. Secure the hose
reel lock (17).
2-18
|