MAINTENANCE OF RSPU
Section VI.
maintenance by the MAC. These tasks are accomplished without dismantling the
unit.
detailed in this paragraph. If the RSPU is found to be faulty, inform DS.
2-7.1 Inspection. Inspect the RSPU as follows:
a.
Inspect for accumulations of dust, grease and for damage.
b.
Check that external components are undamaged. For damaged components,
report to DS for disposition.
WARNING
Adequate ventilation should be provided while using TRICHLOROTRI-
Prolonged breathing of vapor should be avoided. The
FLUOROETHANE.
solvent should not be-used near heat or open flame: the products of
Since T R I C H L O R I F L U R O -
decomposition are toxic and irritating.
ETHANE dissolves natural oils, prolonged contact with skin should be
When necessary, use gloves which the solvent cannot
avoided.
If the solvent is taken internally, consult a physician
penetrate.
immdiately.
moisture, fungus, rust and corrosion. Clean as follows:
a.
Remove dust, dirt, and moisture with a clean soft cloth.
Remove grease, fungus and ground-in dirt from RSPU using a cloth dampened
b.
(but not wet) with trichlorotrifluoroethane, available as freon type TF,
NSN 6850-00-105-3084.
c.
Remove dust and dirt from plugs and jacks with a brush.
Remove dirt/dust from air filters using a stiff brush.
d.
2-7.3 Test.
Test using the system BITE. Refer to TM 32-5865-060-10 for the BITE
procedure.
When necessary, replace lamps in panel indicators as
follows:
a.
Using a small flat tip screwdriver in the groove at the top of the
indicator, gently remove the indicator.
2-3
|