TM 32-5811-024-14&P
MAINTENANCE ALLOCATION CHART FOR DIGITAL PROCESSOR SET AN/USM-433
(1)
(2)
(3)
(4)
(5)
(6)
GROUP
COMPONENT/
MAINTENANCE
MAINTENANCE LEVEL
TOOLS AND
NUMBER
ASSEMBLY
FUNCTION
C
O
F
H
D
EQUIPMENT
REMARKS
0110
CCA, XCVR TEST
INSPECT
.20
A10
TEST
.25
3,5-7
REPLACE
.01
12,14,
29,33
FAULT LOCATE
.25
3,5-7,
12,14,
29,33
REPAIR
.50
16
0111
CCA, ROM
INSPECT
.20
A11
TEST
.25
23,30-32
REPLACE
.01
16
FAULT LOCATE
2.50
1,5-7,
24-26
REPAIR
.52
16
PROGRAM
.50
23,28,
30-32
0112
CCA, ROM
INSPECT
.20
A12
TEST
.25
23,30-32
REPLACE
.01
16
FAULT LOCATE
2.50
1,5-7,
24-26
REPAIR
.52
16
PROGRAM
.50
23,28,
30-32
0113
POWER SUPPLY
INSPECT
.10
A19
TEST
.10
3
REPLACE
.75
8
FAULT LOCATE
.10
3
REPAIR
.50
8
02
CABLE KIT, DGTL PROC
1951-1-1108 CONFIG-1
0201
CABLE ASSY, SP, ELEC
INSPECT
.02
W201
TEST
.80
3
REPLACE
.01
REPAIR
.75
8,10
0202
CABLE ASSY, SP, ELEC
INSPECT
.02
W202
TEST
.80
3
REPLACE
.01
REPAIR
.75
8,10
B-6
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |