Click here to make tpub.com your Home Page

Page Title: CHAPTER 2 OPERATING INSTRUCTIONS
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 3-6910-227-10
CHAPTER 2
OPERATING INSTRUCTIONS
Section I. UNPACKING, INSPECTION, AND REPACKING
NOTE
WARNING
Replacement bottles contain no markings.
Wear protective mask at all times when using
Instructor must code bottle at time of use.
SCAITS.
Don't breathe agent simulant
vapors.  Work in a well ventilated area.
(3) Check that the three simulant bottles are not
Some simulants are corrosive and some are
empty, not broken, and that caps are. secure. Do not
toxic. Breathing simulant vapors may cause
remove caps from the three simulant bottles.
you irritation, discomfort, and injury. Refer to
(4) Decontaminate the SCAITS using a solution
appendix D for specific first aid and medical
of water and detergent (item 4, app C), if simulant bottle
information. Wear gloves when you handle
is broken. Discard broken glass bottle as ordinary trash.
bottles or vials of agent simulants.
If
b. Vial Boxes.
simulants get on your skin, immediately wash
with soap and water.
(1) Remove and open the vial boxes one at a
time.
NOTE
(2) Check that the ampoules within the vials are
not broken. Do not remove ampoules within the vials. If
Observe  warning
labels
on
simulant
ampoules are broken, remove cap from vial, wash cap,
packaging.
vial, and ampoule in solution of water and detergent
(item 4, app C). Discard as ordinary trash.
c. Sampling Adapter Assembly.
2-1. Unpacking SCAITS
Unpack SCAITS as follows:
(1) Remove and inspect the sampling adapter
a. Put on gloves (app B and C).
assembly (fig. 1-2) to make sure it is complete.
b. Remove lever locking ring (fig. 1-1) and lid from
(2) If missing or incomplete, requisition a
replacement sampling adapter assembly (item 3, app C).
pail.
c. Remove TM 3-6910-227-10.
NOTE
d. Remove and save any cardboard packing
The empty test bottles and the sampling
adapter assembly are the only SCAITS parts
material.
that may be requisitioned separately (app C).
e. Remove simulant/test bottle carrier.
If other items, such as the simulants, are
f. Remove vials carrier.
g. Remove sampling adapter carrier.
missing, requisition a new SCAITS and keep
the old, incomplete set for replacement parts.
2-2. Inspection of SCAITS Contents
a. Simulant/Test Bottles.
2-3. Repacking SCAITS
Repack SCAITS components in their respective carriers
(1) Inspect the simulant/test bottles and caps to
(fig. 1-1). Repacking is reverse of unpacking of SCAITS
ensure the test bottles are not broken.
(para 2-1). Repack the pail and store SCAITS until ready
(2) Discard broken bottle as ordinary trash.
for use.
Requisition a replacement bottle (item 2, app C). Retain
cap if serviceable.
Section II. OPERATING UNDER USUAL CONDITIONS
of agent simulants.  If simulants get on your skin,
WARNING
immediately wash with soap and water.
Wear protective mask at all times when
NOTES
using SCAITS.  Don't breathe agent
simulant vapors.
Work in a well
Observe warning labels on simulant
ventilated area.  Some simulants are
packaging.
corrosive and some are toxic. Breathing
simulant vapors may cause you irritation,
If more sampling adapter assemblies are needed, such
discomfort,  and  injury.
Refer  to
as when training several soldiers at the same time on
appendix D for specific first aid and
one SCAITS, these assemblies may be requisitioned
medical information.
separately (item 3, app C).
Wear gloves when you handle bottles or vials
Change 3 2-1

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business