4240-01-055-1493)">
|
|
TM 3-4240-302-30&P-6
2-7. AIRFLOW VALVE (CONT).
LOCATION
ITEM
ACTION
REMOVAL (CONT)
Airflow Valve
Motor with RFI filter FL2
5.
Remove four nuts (12) and screws (13).
6.
Remove motor mount (14) with motor and RFI
filter from airflow valve (15).
7.
Loosen setscrew (16) and remove gear (17).
8.
Remove four nuts (18) and screws (19).
9.
Remove motor (20) and RFI filter FL2 (8) from
motor mount (14).
10. Remove screw (21), washer (22), and
grounding wire (23).
INSTALLATION
1.
Install groundin g wire (23) on motor (20) with
washer (22) and screw (21).
2.
Install motor (20) in motor mount (14) using
four screws (19) and nuts (18).
3.
Install gear (17) on shaft of motor (24). Align
setscrew hole in gear with hole in motor shaft.
Apply sealing compound (item 1, app C) to
setscrew. Install and tighten setscrew (16).
4.
Install motor mount (14) with motor and RFI
filter in airflow valve (15) using four nuts (12)
and screws (13).
5.
Solder wires (6 and 7) to lugs on RFI filter FL2
(8). Refer to wiring diagram (p. 2-19).
6.
Install RFI filter FL2 (8) and grounding wire (23)
in airflow valve (15) using screws (14) and nuts
(5).
2-10
|