TM 3-1040-279-12&P
e. Quick Disconnect Coupling.
REMOVAL
NOTE
Removal and installation procedures are the
same for both disconnects. Disconnect brack-
et shown removed for clarity.
1. Disconnect hose (1) from disconnect coupling (2).
2. Disconnect swivel adapter (3) from disconnect coupling (2).
3. Disconnect nut (4) and washer (5) and remove disconnect coupling (2) from disconnect bracket (6).
INSTALLATION
1. Position disconnect coupling (2) in disconnect bracket (6) and secure with nut (4) and washer (5).
2. Connect swivel adapter (3) to disconnect coupling (2).
3. Connect hose (1) to disconnect coupling (2).
|