TM 3-1040-279-12&P
4-26 NOZZLE ASSEMBLY.
This task covers repair of Nozzle.
INITIAL SETUP
Tools
General Mechanic's Automotive Tool Kit
SC 5180-90-CL-N26
Equipment Condition
Nozzle assembly removed from smoke gener-
ator (P. 4-22).
General Safety Instructions
Before performing any maintenance proce-
dures be sure circuit breaker CB1 is in OFF
position.
DISASSEMBLY
1. Remove three screws (1) and washers (2) and disassemble nozzle assembly (3).
2. Remove nozzle (4) from support assembly (5).
REASSEMBLY
1. Install nozzle (4) on support assembly (5).
2. Reassemble nozzle assembly (3) with three screws (1) and washers (2).
Change 3
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |