TM 3-1040-279-12&P
4-16 EQUIPMENT CONTAINER ASSEMBLY (CONT).
k. Purge Air Hose Assembly.
REMOVAL
NOTE
Equipment container removed from smoke
generator for clarity.
1. Loosen two screws (1) securing sides of cover assembly (2). Remove two screws (3), lockwashers
(4), and washers (5) securing top of cover assembly and open cover assembly.
2. Remove eight screws (6) and washers (7), securing equipment container panel (8).
3. Disconnect purge air hose (9) from elbow (10) on equipment container (11).
4. Disconnect four screws (12), washers (13), and lock washers (14) securing terminal bracket
assembly (15).
5. Remove purge air hose (9) from solenoid assembly (16).
INSTALLATION
1. Connect purge air hose (9) to solenoid assembly (16).
2. Position terminal bracket assembly (15) and secure with four screws (12), washers (13) and lock
washers (14).
3. Connect air hose (9) to elbow (10) on equipment container (11).
4. Make sure switches on terminal bracket are in the OFF (down) position.
5. Position equipment container panel (8) and secure with eight screws (6) and washers (7).
6. Slowly close cover assembly (2). Position hoses in equipment container while closing cover so
that hoses do not become kinked or pinched. Secure cover assembly with screws (1 and 3),
lockwashers (4), and washers (5).
Change 2
|