TM 3-1040-279-12&P
4-16 EQUIPMENT CONTAINER ASSEMBLY (CONT).
e. Relay K101.
REMOVAL
1. Remove eight screws (1) and washers (2) securing equipment container panel (3).
2. Tag and remove electrical connections from relay (4).
3. Disconnect resistor (5) lead from terminal board (6) and tag.
4. Remove four screws (7) and washers (8) securing relay (4) and remove relay.
5. Remove screw (9) and nut (10) securing resistor (5) and loop clamp (11) to relay (4).
INSTALLATION
1. Secure resistor (5) and loop clamp (11) to relay (4) with screw (9) and nut ( 10).
2. Secure relay (4) in equipment container with four screws (7) and washers (8).
3. Attach electrical connections to relay as tagged. Connect resistor (5) lead to terminal board (6) as
tagged. Coat terminal board screw thread with sealing compound (11A, App E) before securing.
4. Install equipment container panel (3) with eight screws (1) and washers (2).
Change 2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |