TM 3-1040-279-12&P
4-16 EQUIPMENT CONTAINER ASSEMBLY (CONT).
d. Ignition Coil.
REMOVAL
1. Remove equipment container (P. 4-68).
2. Loosen two screws (1) securing sides of cover assembly (2). Remove two screws (3), Lock washers
(4), and washers (5) securing top of cover assembly and open cover assembly.
3. Remove eight screws (6) and washers (7) from equipment container panel (8) and remove panel.
4. Remove ignition cable (9) from ignition coil (10).
5. Tag and remove two ignition coil (E11) wires from terminal bracket assembly (11). See smoke
generator wiring (P. 4-34).
6. Tag and remove resistor assembly (12) lead from terminal bracket assembly (11).
7. Remove four screws (13) lock washers (14), and flat washers (15) securing terminal bracket
assembly (11).
8. Remove four screws (16) and washers (17) securing relay (18). Move relay and terminal bracket
aside.
9. Remove two screws (19), two washers (20), two nuts (21) and one electrical wire (22), and
remove ignition coil (10) from equipment container (23).
INSTALLATION
1. Position ignition coil (10) in equipment container (23).
2. Install two screws (19), two washers (20), one electrical wire (22), and two nuts (21), and secure
ignition coil (10) to equipment container (23).
3. Position relay (18) and secure with four screws (16) and washers (17).
4. Install two ignition coil wires on terminal bracket assembly (11) as tagged.
5. Install ignition cable (9) on ignition coil (10).
6. Position terminal bracket assembly (11) in equipment container (23) and secure with four screws
(13), lock washers (14) and flat washers (15).
7. Attach resistor assembly (12) to terminal bracket assembly (11).
8. Position equipment container panel (8) and secure with eight screws (6) and washers (7).
9. Close cover assembly (2) and secure with four screws (1 and 3) and lock washers (4) and
washers (5).
10. Install equipment container (P. 4-68).
Change 2
|