TM 3-1040-279-12&P
2. Loosen two screws (2) securing sides of cover assembly (3). Remove two screws (4), lockwashers
(5), and washers (6) securing top of cover assembly and open cover assembly.
REASSEMBLY
1. Connect cable and hose assemblies (1) to front of cover assembly.
2. Check for leaks:
(a) Set circuit breaker CB1 and POWER switch to ON.
(b) Hold FUEL switch in START until FUEL indicator lights, then release to RUN.
(c) Check hose and tube assembly connections for leaks. Tighten or repair connections.
(d) Set all switches to OFF.
3. Slowly close cover assembly (3). Position hoses in equipment container while closing cover so
that hoses do not become kinked or pinched. Secure cover assembly with screws (2 and 4),
lockwashers (5), and washers (6).
Change 2
|