|
|
TM 3-1040-279-12&P
ORGANIZATIONAL PREVENTWE MAINTENANCE
CHECKSAND SERVICES QUARTERLY SCHEDULE (CONT)
PROCEDURES
ITEM TO BE INSPECTED
ITEM NO.
i. Remove fuel supply hose end (4) from fuel
filter/water separator assembly outlet and fuel
return hose end (5) from fuel can lid assembly (6).
CAUTION
Do not let end of hose come into contact with
dirt or any other contaminants while
performing this procedure. Foreign matter
allowed to enter into the fuel system will
damage internal fuel pump parts.
j. Place both fuel hose ends in a container of light
10W grade lubricating oil (NSN 9150-00-189-6727).
k. Power-up the Control-Indicator Panel and place
the FUEL switch in the START (up) position until
fuel indicator illuminates. With fuel indicator
illuminated, move the FUEL switch to the ON
(middle) position. Run the fuel pump for a minimum
of two minutes to flush moisture out.
I. Place FUEL switch in the OFF (down) position
and turn-off Control-Indicator Panel power.
m. Connect fuel supply hose end (4) and fuel
return hose end (5) to fuel can lid assembly (6).
4-4.3/(4-4.4 Blank)
Change 4
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |