T M 3-1040-279-12&P
ORGANIZATIONAL PREVENTIVE MAINTENANCE
CHECKS AND SERVICES QUARTERLY SCHEDULE
PROCEDURES
ITEM TO BE INSPECTED
ITEM NO.
Fog Oil Pump Pressure Relief valve
Adjust pressure relieve valve (P. 4-145).
1
Air Compressor Assembly
2
Clean mechanical felt (filter).
There are two air filters on the
compressor assembly. Procedures
are the same for both filters.
a. Turn air filter (1) turn counterclockwise.
b. Remove mechanical felt (2) from air com-
pressor (3).
c. Clean mechanical felt (2) with dry cleaning
solvent (Item 4, App E) or replace as required.
d. Install air filter (1) on air compressor (3)
and turn turn clockwise to secure.
4-3
|