TM 3-1040-214-12
down to fill the diffusion tube with solution.
disconnect the diffusion tube nut (8) from the safety
valve adapter (9).
(20) Submerge the tank group
in
a
(7) Remove and retain the pressure regulator
decontaminating solution for 30 minutes.
and attaching parts.
b. Decontaminating and Cleaning.
(8) Disconnect the tube assembly (16) from
(1) After 30 minutes have elapsed, remove
the inlet adapter (17).
the tank group from the solution.
(9) Using pressurized air (between 25 psi and
(2) If required, scrub the exterior surfaces of
35 psi), clean the air passages in the disconnected parts
the agent tank and carrier parts to remove any visible
of any agent (or T1 talc) as follows:
agent.
(3) Remove tape from both pipe and cap
WARNING
assemblies (4). Remove both pipe and cap assemblies.
Never stand in the way of pressurized
With a wire clean the cap holes (fig. 4-6).
air.
(4) Using a brush, clean all threads of any
foreign deposits.
(10) Apply air pressure to the inlet adapter (17)
located on the bottom of the pressure regulator (18).
(5) Dump the solution in the agent tanks into
This operation will clean the air passage in the pressure
a chemical disposal system.
regulator (18) and safety valve (11).
(6) Remove plug from diffusion tube.
(11) Apply air pressure to the opening in the
(7) Flush the interior of the agent tanks and
bottom of the safety valve adapter (9). This operation
all exterior surface including the carrier parts with clean
will clean the air passage in the safety valve adapter (9)
water.
and hose assemblies (2).
(8) Dry the parts with a clean cloth and
(12) Open the shutoff valve (22). Apply air
thoroughly dry with pressurized air (5 to 10 psi).
pressure to the end of the vent tube (21). This operation
Thoroughly dry the interior of the agent tanks to prevent
will clean the air passage in the shutoff valve (22) and
corrosion. Minor internal surface corrosion in the agent
diffusion tube adapter (9).
tank is acceptable.
(13) If air cannot be detected coming out of the
(9) When all parts are cleaned and dry,
diffusion tube adapter (9), perform the following
recheck possible deposits of agent by sniffing.
If
operation: Clean adapter air passage with a wire and
required, repeat decontaminating procedure.
perform step (12) above.
c. Assembly.
(14) Obtain a plug from the M27 service kit
(TM 3-1040-221-12).
Close the open end of the
(1) Install pipe a d cap assemblies (4) and
n
diffusion tube (5) with the plug.
tighten.
(15) Remove one pipe and cap assembly (4).
(2) Position the tube assembly (16) as shown
in figure 4-5. Connect the tube assembly (16) to the inlet
(16) Pour decontaminating solution (para 4-
adapter (17) and tighten.
from the top.
(3) Hold the pressure regulator in a position to
tighten the diffusion tube nut (8) to the adapter (9).
(17) Install the pipe and
cap
assembly
(removed in (15) above) and tighten.
(4) Cross both hose assemblies (2) and
connect each hose assembly quick-disconnect coupling
(18) Tape and seal open ends on the pipe and
half (3) to the pipe and cap assemblies (4).
cap assemblies (4).
(5) Connect the carrier pack to the frame with
(19) Shake the agent tanks several times to
the cotton cord.
agitate the solution in the tanks. Turn agent tank upside