TM 3-1040-214-12
Section II. SERVICING
(7) Rotate the ball depressing ring (step C) on
4-7. General
the hose coupling until the slot in the ring is in line with
This section describes the method used to fill the agent
the lock pin. Pull back the ball depressing ring on the
tanks with riot control agent (or T1 talc for test firing). It
hose coupling. Connect hose coupling to the agent
also includes information for pressurizing the pressure
delivery pipe tank coupling (step D).
tanks.
(8) Allow the ball depressing ring to en gage
the balls. Make certain that the coupling is secured.
4-8. Filling Agent Tanks
Rotate the ball depressing ring so that the slot is not in
Agent tanks filled with riot control agent (or T1 talc) must
line with the lock pin.
be kept in an upright position. This will prevent agent (or
(9) Disconnect the hose assemblies from the
T1 talc) from entering and blocking the air passages in
pipe and cap assemblies. Remove the pipe and cap
the diffusion pipe and hose assemblies (Fig. 1-7).
assemblies.
Agent (or T1 talc) may be issued in plastic containers (a
below) or bags (b below). One bag or container is
sufficient to fill both agent tanks. Filling operations
NOTE
should be performed outdoors and in a remote area
If the interior surface of the agent
away from personnel not assigned to these operations.
tank shows signs of minor corrosion,
the agent tank should still be used.
WARNING
(10) Don protective mask, protective mask
Personnel must wear a protective
hood, and rubber gloves.
mask, protective mask hood, and
rubber gloves when filling the agent
(11) Tilt the M3 disperser (Fig. 4-4). Insert the
tank with agent.
container spout into the opening of one of the agent
tanks.
a. Agent in Plastic Containers.
(12) Apply and release pressure on the sides
of the container to force agent from the containers into
(1) Obtain the following protective equipment
the agent tank. Perform this operation until the agent
for personnel involved in filling operations:
tank is filled.
(a) Protective mask.
(13) Fill the second agent tanks ((11) and (12)
(b) Protective mask hood.
above).
(c) Rubber gloves.
(14) Remove agent that may have become
(2) Obtain one container of agent.
lodged in the tank threads.
(15) Reinstall the pipe and cap assemblies
NOTE
removed in (9) above). Handtighten pipe and cap
Agent in one container is sufficient to
assemblies.
fill both agent tanks.
(16) Cross both hoses as shown in figure 1-6
and connect them to the pipe and cap assemblies.
(3) Close the pressure tank valve by turning
(17) Close shutoff valve opened in (4) above.
the valve handle (Fig. 2-1) clockwise.
(18) Perform the following operations if agent
(4) Open the shutoff valve by turning the
has been spilled on the exterior of the equipment.
shutoff valve handle (Fig. 2-1) counterclockwise.
(a) Dampen a rag or sponge with
decontaminating solution (para 4-13a).
NOTE
(b) Wipe the agent off the exterior
surfaces.
If a hissing noise is heard, wait until
it stops.
(c) Place the rag or sponge in the
decontaminating solution for 30 minutes.
(d) Rinse sponge and rag in clean
(5) Remove the coupling cap (Fig. 2-2) from
water and air-dry.
the agent delivery pipe (step A). Install coupling cap on
coupling cap holder (step B).
(e) Dispose of the used solution
(6) Check to see that the rubber gasket in the
ball depressing ring is not missing and is in place (step C).
4-5
|