Click here to make tpub.com your Home Page

Page Title: ADJUSTMENTS
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 11-6665-209-40
ADJUSTMENTS
NOTE
P e r f o r m the following steps when electron tube V102 has been
replaced.
a. Adjustment of Resistor R106.
(1) Connect test equipment as shown below.
(2) Adjust resistor R106 until 1 volt is recorded on the voltmeter.
NOTE
Perform the following steps when any of the following components
have been replaced (V103, V104, and Q105).
b. Adjustment of Resistor R117.
(1)
Set the range switch S102 to 50 mR/hr range.
(2)
Rotate resistor R117 clockwise until the radiacmeter indicates full scale.
Connect test equipment as shown below.
(3)
(4)
S l o w l y rotate resistor R117 counterclockwise until the multimeter indicates
the lowest reading.
(5) C o n t i n u e rotating resistor R117 counterclockwise until the multimeter in-
dicated 0.5 0.1 vdc higher then the reading in step 4 above.