Section V. MODE 4 ALIGNMENT USING AN/TPM-25A
5.1-18. General
procedure used conventional test equipment in
conjunction  w i t h t h e R a d a r T e s t S e t
The test equipment listed in paragraph 5.1-19, or
AN/TPM-25A. The second procedure used the
approved equivalent, is required to perform
Radar Test Set AN/UPM-137A. Refer to figure
alignment procedures. Two procedures are
5.1-10 for adjustment control location.
provided for each alignment procedure. The first
5.1-19. Test Equipment Required for Alignment
Technical Manual
Test Equipment
Oscilloscope AN/USM-281A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TM 11-6625-1703-14
Radar Test Set AN/TPM-25A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TM 11-6625-2610-12
Mulitmeter TS 352B/U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TM 11-6625-366-15
Mulitmeter ME 26B/U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TM 11-6625-200-15
Test Set, Radar AN/UPM-137A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NAVELEX 0969-158-1010
NAVAIR 16-30UPM137-6-1
AIR FORCE T.O.
33A1-3-426-21-1 AND
NAVELEX 096-158-1020
NAVAIR 16-30UPM137-6-2
AIR FORCE T.O.
33A1-3-426-21-2
5.1-20. Power Supply Adjustment
c. Connect dc test probe to test point A3TP1.
d. Apply power to equipment and permit
a.Connect equipment as shown in figure 3-1.
5-minute warmup.
b. Set the ME-26B/U RANGE control to 10V.
e. Adjust test set control A3R24 unti
c. Connect the ME-26B/U dc probe to test
AN/UPM-137A oscilloscope display indicates 5
point A3TP1.
0.l vdc.
d. Adjust control A3R24 until the ME-26B/U
f. Connect equipment as shown in figure 5.1-2.
indicates 5 0. 1 volts.
g. Set TS-352B/U FUNCTION switch to DC
e. Disconnect the ME-26B/U from the test set.
+ CURRENT and RANGE switch to 500MMA.
f. Connect the equipment as shown in figure
h. Adjust control A3R3 for meter indication o
400 20 ma.
g. Set the TS-352B/U FUNCTION switch to
DC + CURRENT and range switch to 500MA.
5.1-22. Mode 4 Receiver Sensitivity and Reply
h. Adjust control A3R3 for a multimeter in
Video Adjustments Using AN/TPM-25A
dication of 400 20 milliamperes.
a. Set and adjust the AN/TPM-25A control:
as follows:
5.l-21. Power Supply Adjustment Using
AN/UPM-137A
REPLIES panel
MODULATION SEL: M4-3P
a. Connect equipment as shown in figure 3-1.1.
REPLY WIDTH: 0.45
b. Set and adjust AN/UPM-137A oscillo-
SUB PULSE SEL: OFF
scope controls as follows:
RANGE DELAY SEL (USEC) :0001
MEASUREMENT PANEL:
Control
Position
Horizontal SYNC
EXT DC
PRF RANGE: X100
1O SEC
HORIZONTAL TIME/DIV
FUNCTION SEL: PRF CHAL
DISPLAY-CHAN A/ALT CHAN B
CHAN A
DEMOD VID LEVEL: Mid position
VERTICAL CHAN A-75  IN/OUT
OUT
SIF CHAL VID panel
VERTICAL CHAN A-AC/DC
DC
SIF MODE SEL: OFF
VERTICAL CHAN A-VOLT/DIV
1
20V/5BV: 5V
..
5.1-31
Change 5