Section
III.
MODE 4
ALIGNMENT
p r o v i d e d for each alignment procedure. The first
NOTE
procedure uses conventional test equipment in
See  Section  V  when
using
with  the  Radar  Test  Set
conjunction
AN/TPM-25A.
AN/UPM-98A and AN/UPM-98B. The second
5.1-10. General
procedure  uses
the  Radar  Test  Set
AN/UPM-137A. Refer to figure 5.1-10 for ad
The test equipment listed in paragraph 5.1-11, or
j u s t m e n t control location.
approved equivalent, is required to perform
a l i g n m e n t  p r o c e d u r e s .  TW O p r o c e d u r e s  a r e
5.1-11. Test Equipment Required for Alignment
Technical manual
Test equipment
TM 11-6625-1703-14
Oscilloscope AN/USM-281A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wattmeter AN/URM-98 (including Test Set, Radio Frequency Power
TM 11-6625-433-13
TS-779A/U and Bolo Meter, Radio Frequency MX-2144A/U) . . . . . .
Test Facilities Set, Transponder Test Set AN/APM-270(V). . . . . . . . . .
TM 11-6625-1644-12
TM 11-6625-299-15
Generator, Signal AN/URM-64A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modulator MD-796
TM 11-6625-366-15
Multimeter TS 352 B/U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Multimeter ME 26B/U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TM 11-6625-200-15
Test Set, Radar AN/UPM-137A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NAVELEX 0969-158-1010
NAVAIR 16-30UPM137-6-1
AIR FORCE T.O.
33AI-8-426-21-1  AND
NAVELEX 0969-158-1020
NAVAIR 16-30UPM 137-6-2
AIR FORCE T.O.
33AI-3-426-21-2
5.1-13. Mode 4 Receive Sensitivity and Reply
5.1-12. Power Supply Adjustment
Video Adjustments
a. Connect equipment as shown in figure 3-1.
a. S e t a n d a d j u s t t h e A N / A P M - 2 7 0 ( V ) c o n -
b. Set the ME-26B/U RANGE control to 10V.
c. C o n n e c t t h e M E - 2 6 B / U d c p r o b e t o t e s t
trols as follows:
(1) CONSECUTIVE REPLIES to 64.
point A3TP1.
(2) SPACING PULSE 2 to 0.
d. A d j u s t c o n t r o l A 3 R 2 4 u n t i l t h e M E - 2 6 B / U
(3) SPACING PULSE 3 to 0.
indicates 5 0.1 volts.
( 4 ) SYNC GAIN to midposition.
e . Disconnect the ME-26B/U from the test set.
( 5 ) REPLY MODULATION 1X-2X to 1X.
f. C o n n e c t t h e e q u i p m e n t a s s h o w n i n f i g u r e
b. Set the transponder test set controls as
follows:
g. S e t t h e T S - 3 5 2 B / U F U N C T I O N s w i t c h t o
(1) FUNCTION to SYSTEM.
D C + CURRENT and range switch to 500MA.
h. A d j u s t c o n t r o l A 3 R 3 f o r a m u l t i m e t e r i n
(2) MODE to 4.
dication of 400 20 milliamperes.
(3) DIR-RAD to RAD.
(4) ISLS to OFF.
c. A p p l y  P O W E R  T O  T H E  E Q U I P M E N T
A N D PERMIT A 14-minute warmup period.
5.1-20