Main Trigger Coupling: AC
Display:A
A VOLTS/DIV 10
a. S e t the AN/UPM-98 SUB PULSE a. None.
ME-26B/U
3
SELECT switch to Cl information pulse
RANGE: 30V
position.
SELECTOR: (+)
b. Adjust the SUB PULSE POS control b. None.
until the test set barely indicates
REJECT. Adjust the ME-26B/U ZERO
SET to zero meter.
c. Adjust the AN/UPM-96 SUB PULSE c. None.
POS control until test set set indicates
ACCEPT. Note ME-26B/U indication.
d. Adjust the SUB PULSE POS control, in d . T h e t e s t s e t w i l l
provide an ACCEPT
either direction, until the test set barely
indication when 80%
i n d i c a t e s REJECT. Note the ME-
or more replies are
26B/U indication. This voltage should
correct.
be 80% of that noted in c above.
|