Click here to make tpub.com your Home Page

Page Title: Sectionalization Test Using AN/TPM-25A-cont.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Control settings
Normal
Paragraph
Indication
reference
Procedure
Equipment under test
Test equipment
Step
c. sensitivity -9
c . C a l c u l a t e t h e t e s t s e t  sensi
LOCK FUNCTION:
REPLY WIDTH: 0.45
9
tivity by adding SUM ATTEN dial
SYSTEM
(Cont)
dBm.
reading and the 1000 MHz insertion
SIF REPLY CODE: 7777
loss of cable 45413-139526.
SUB PULSE SEL: OFF
d. Adjust SUM ATTEN dial for a
d. None.
RANGE DELAY SEL: 0100
reading of 3 dB less than that in step
GATING PASS 00
b.
GATING INHIBIT 00
SIF CHAL VID SIF
MODE SEL OFF
TRIG SEL INT DCD/
EXT INT
SIG GEN FUNCTION:
FIXED FREQ
SUM ATTEN: 0 DB. All
other switch settings
immaterial.
a. Refer to figure 8-36.
a. Connect the oscilloscope A INPUT
AN/USM-281A DISPLAY:
10
probe (Figure 3-25) to each of the
A MAIN TIME/DIV
following test points in the order
DELAYED TIME/
g i v e n to perform receiver and
DIV as required for wave-
decoder tests. Observe whether the
form
pulses are normal.
(1) 3-6j.
(1) A10TP5(video enable delay) . . . .
(2) 3-6i.
(2) A9TP4 (video enable output) . . . .
(3) 3-6k.
(3) A11TP1 (video shaper output) . . .
(4) 3-6i.
(4) A9TP3(line drive enable out-
put . . . . . . . . . . . . . . . . . . . . . . .
(5) 3-6j.
(5) A10TP4 (line drive pulse) . . . . . . .
(6) 3-6j.
(6) A10TP2 (delay line pulse) . . . . . .
(7) 3-6j.
(7) A10TP1 (delay line main gate
input) . . . . . . . . . . . . . . . . . . . .
(8) A11TP2 (comparison pulse
shaper output). . . . . . . . . . . . .
(8) 3-6k.
(9) 3-6j.
(9) A10TP6 (read delay) . . . . . . . . . . .
(10) 3-6k.
(10) A12TP4 (error blanking) . . . . . . .
b. Indications are
b. Check the following dc levels with
(1) 7-12 volts dc.
(1) A11TP6 (error detector output.
Set AN/TPM-25A SIF REPLY
CODE switches to 7776 to
observe low & level. Return
switches to 7777 to observe
normal indication.