NOTES
UNLESS OTHERWISE INDICATED
1. ALL MEASUREMENTS ARE FROM DESIGNATED TERMINAL TO CHASSIS. VOLTAGE SHOWN ABOVE LEAD
ABOVE LEAD LINES, RESISTANCES BELOW. VOLTAGES SHOWN FOR NON-DIGITAL CIRCUITS ONLY
2. VOLTAGES MEASURED WITH MULTIMETER NO SIGNAL CONDITIONS
3. REMOVE MODULE FORM EQUIPMENT TO MAKE RESISTANCE MEASUREMENTS. MAKE
MEASUREMENTS WITH MULTIMETER TS-352/U, R x100 RANGE FOR INDICATED RESISTANCES
10K OR BELOW, AND RX 10K RANGE FOR THOSE ABOVE 10K. FIRST READING WITH
NEGATIVE LEAD TO CHASSIS, SECOND WITH LEADS REVERSED
4. PREFIX REFERENCE DESIGNATIONS WITH A14
TM6625-667-35-58
Figure 3-9. 150-volt power supply voltage and resistance diagram.