TM 11-6625-667-45/NAVSHIPS 0969-249-8010/NAVAIR 16-30APM123-2/TO 33A1-3-367-22
NOTES:
UNLESS OTHERWISE INDICATED
1. ALL MEASUREMENTS ARE FROM DESIGANTED TERMINAL CHASSIS. VOLTAGES SHOWN
ABOVE LEAD LINES, RESISTANCES BELOW. VOLTAGES SHOWN FOR NON-DIGITAL CIRCUITS ONLY
2. VOLTAGES MEASURED WITH MULTIMETER ME-26/U, NO SIGNAL CONDITIONS
3. REMOVE MODULE FROM EQUIPMENT TO MAKE RESISTANCE MEASUREMENTS. MAKE
MEASUREMENTS WITH MULTIMETER TS-352/U, R x100 RANGE FOR INDICATED RESISTANCES
10K OR BELOW, AND R X10K RANGE FOR THOSE ABOVE 10K. FIRST READING WITH
NEGATIVE LEAD TO CHASSIS, SECOND WITH LEADS REVERSED
TM6625-667-35-59
4. PREFIX REFERENCE 0ESIGNATIONS WITH A13
Figure 3-8. 12-volt regulator and resistance diagram.