Click here to make tpub.com your Home Page

Page Title: Sectionalization Tests Using AN/UPM-137A.-CONT.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Control settings
Normal
Paragraph
Equipment
indication
reference
Procedure
under test
Test equipment
Step
VERTICAL-CHAN A-VOLT/
DIV: 5
VERTICAL-CHAN B-AC/DC:
DC
VERTICAL-CHAN-B-75W/
OUT: OUT
VERTIAL-CHAN B-VOLT/
DIV: 5
CALIBRATORS-XTAL MARK
(SEC): OFF
CALIBRATORS-LEVEL:
Midposition
Same as step7 . . . . . . . . . . . . . . . . . . Same as step 7. . . . . . . . . . a. Connect AN/UPM-137A oscilloscope VERTI- a. Refer to figure 8-36.
8
CAL-CHAN A-VIDEO IN jack to following
test points in order given. Observe whether
pulses are normal.
(1) 3-6j
(1) A10TP5 (video-enable delay).
(2) 3-6i
(2) A9TP4 (video-enable output).
(3) 3-6k
(3) A1lTP1 (video-shaper output).
(4) A9TP3 (line-drive enable output).
(5) 3-6j
(5) A10TP4 (line-drive pulse).
(6) 3-6j
(6) A10TP2 (delay-line pulses).
(7) 3-6j
(7) A10TP1 (delay-line main gate input).
(8) 3-6k
(8) A11TP2 (comparison pulse-shaper output).
(9) A10TP6 (read relay).
(9) 3-6j
(10) 3-6i
(10) A12TP4 (error blanking).
b. Connect AN/UPM-137A oscilloscope VERTI-  b. Indications are-
CAL-CHAN A-VIDEO IN jack to following
teat points in order given. Verify that cor-
a. None.
rect dc levels are present.
(1) 7 to 12 volts dc.
(1) A11TP6 (error detector output).
b. None.
(2) 7 to 12 volts dc.
(2) A12TP3(readout) . . . . . . . . . . . . . . . . . . .
When REJECT
indicator is
lighted.
c. Repeat a(2) through (10) above with test set  c. Indications should be the
same as in a above.
MODE switch at C, 3/A, TEST, and 1 re
spectively.
d. Set test set CODE switches to 7700 and  d. None.
MODE switch to 2. Set AN/UPM-137A SIS
generator SIF 1 CODER-Code switches to
7700.
e. Set AN/UPM-137A SIS generator SIF 1 COD-  e. Waveform in figure 8-36
(A9TP4).
ER-FUNCTIONAL SEL switch to I/P and

Privacy Statement - Press Release - Copyright Information. - Contact Us