Click here to make tpub.com your Home Page

Page Title: Table 8-4. Monitor Reply Evaluator (A3), Troubleshooting
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

T.O. 12P4-2APX-192
NAVAIR 16-35TS1843-1
TM 11-6625-1646-25
Table 8-4. Monitor Reply Evaluator (A3), Troubleshooting (See figure FO-4)
Test
Test
Control Settings
Normal
If Indication
Step
Point
Equipment
and Instructions
Indication
Is Normal
If Indication Is Abnormal
1
P13 of
Test set-up
Set-up oscillo-
Refer to
Proceed to
Replace A4 module. Depot
A3
scope for external
step 2.
level maintenance re-
(D)
and A3
triggering; place
quired.
extender
RAD TEST-MON
board.
switch on C-6280
in MON position.
Set-up AN/UPM-
98A controls per
step 5.
2
B1 of
Same as
Same as step 1.
Same as
Proceed to
Check Q3, Q4, Q8 and as-
Q4
step 1
step 1.
step 3.
sociated components.
(E)
Replace defective com-
ponent(s).
3
Collector Same as
Same as step 1.
Proceed to
Check Q3 thru Q8 and as-
of Q6
step 1
step 4.
sociated components.
Replace defective com-
2 SEC
ponent(s).
MIN
4
Base of
Same as
Same as step 1.
Same as
Proceed to
Check CR12, Q9 thru Q11
Q12
step 1
step 1.
step 5.
and associated components.
(F)
Replace defective com-
ponent(s).
5
Visual
None
None
Indicator
Proceed with
Check Q12, Q13, Q14 and
remains
routine
associated components.
on for a
troubleshoot-
Replace defective com-
minimum
ing pro-
ponent(s).
of two
cedures on
seconds.
A3 module.
Table 8-5. Mode Generator (A2), Troubleshooting (See figure FO-2)
Test
Test
Control Settings
Normal
If Indication
Step
Point
Equipment
and Instructions
Indication
Is Normal
If Indication Is Abnormal
1
Collector
Test set-up
Place RAD TEST-
Refer to
Proceed to
Check Q3, Y1 and associ-
of Q3
MON switch on
step 2.
ated components. Replace
(A)
and A2
C-6280 in OUT
defective component(s). If
extender
position. Place
Q3, Y1 and associated com-
board
one of the MODE
ponents are okay, replace
selector switches
A2 module. Depot level
in TEST position.
maintenance required.
2
Collector
Same as
Same as step 1.
Same as
Proceed to
Check Q1, Q2 and associ-
of Q2
step 1
step 1.
step 3.
ated components. Replace
(B)
defective component(s).
3
TP1
Same as
Same as step 1.
Same as
Proceed to
Replace A2 module. Depot
(2)
step 1
step 1.
step 4.
level maintenance required.
4
TP2
Same as
Same as step 1.
Same as
Proceed with
Check Q4, Q5, Q6 and as-
(3)
step 1
step 1.
routine
sociated components. Re-
troubleshoot-
place defective com-
ing pro-
ponent(s).
cedures on
A2 module.
8-12

Privacy Statement - Press Release - Copyright Information. - Contact Us