Click here to make tpub.com your Home Page

Page Title: INSPECTION REQUIREMENTS-CONT.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

ELECTRICAL
SERVICE
CARD NO.
MAN
WORK
WORK UNIT
7 Day Inspection
INSPECTION
POWER
ON
IN
1-005
MIN
AREA
SYSTEM
SUB-SYS
REQUIREMENTS
(Cont'd from card 1-004)
0005
M.
Remove protective screen from back of rack. On the rear of the Battery
Disconnect Panel 1A14, connect the alligator clip on the insulated test
lead to the ground bus. Momentarily touch the probe end to terminal E on
VCR2. This action should trip circuit breaker CB2 to the OFF position,
light BAT FAIL lamp 1A14 and initiate the external alarm.  Remove
alligator clip from ground bus and restore circuit breaker to ON position.
Replace protective screen on the back of the rack.
CARD NO.
WORK AREAS
TYPE MECH RQR
MECH NO.
CARD TIME
PUBLICATION
T.O. 31W2-4-203-6WC-1
NUMBER
T.M. 11-6130-363-14-1/2
1-005
0020
U.S. GOVERNMENT PRINTING OFFICE 1972- 759-509/16

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business