TM 11-5995-208-24&P-1
CONNECTOR UG-1870A/U REPLACEMENT (CONT)
CAUTION
Be careful not to crossthread the gland retaining nut (6) when installing it into back-end
body (7).
38. Install gland retaining nut (6) onto back-end body (7).
CAUTION
Maximum torque of gland retaining nut (6) must not exceed 23 inch-pound. This torque
limit is sufficient to cause grip to bite into outer cable jacket.
Shoulder of gland retaining nut (6) must bottom against back-end body (7).
39. Using a torque Wrench, torque gland retaining nut (6) to 24-28 inch-pounds.