TM 11-5995-208-24&P-1
CONNECTOR UG-1870A/U REPLACEMENT (CONT)
NOTE
In order to meet cable retention requirements of final assembly, it is important that after
combing out outer copperweld braid, the folding back operation must be performed in
groups of four strands. One group should not cross the next as they are folded over outer
cable jacket (2).
11. Comb out outer copperweld braid (1), and fold back over outer cable jacket (2).
12. Remove binder/RFl shields (3), allowing 1/16 of an inch maximum of foil wrap to extend
from copperweld braid (l).
13. Comb out cable fillers (4), splaying out and folding back equally over outer copperweld
braid (1).
14. Using masking tape (5), tape down outer copperweld braid strands and paper fillers (6).
NOTE
Be sure no coaxial braid strands (7) lay against forward end of dielectric (8), when
flaring inner cable coaxial braids (7).
15. Slightly flare inner cable coaxial braids (7) away from dielectrics (8).