CONNECTOR UG-1870A/U REPLACEMENT (CONT)
NOTE
Round WD-37A/U cable has fillers. Oval WD-37/U cable has no fillers.
A binder/RFl shield consisting of polyester-aluminum laminate tape is under outer
braid. Trim this binder/RFl shield along with outer braid and fillers.
Binder/RFl shield and cable fillers should be trimmed flush with outer copperweld braid.
6.  Trim outer copperweld braid (1) and cable fillers (2) to 13/16 1/16 of an inch from outer
cable jacket.
7. Slide braid retaining nut (3) over both coaxial cables (4), and push them back out of
the way.
CAUTION
Be careful not to nick or cut coaxial braid.
8. Trim coaxial jacket (5) 15/32 1/32 inches from outer copperweld braid (6).