CONNECTOR UG-1870A/U REPLACEMENT (CONT)
NOTE
Be sure to install correct cable sealing gland (4). There are two variations: one with a
round hole for WD-37A/U cable, and one with an oval hole for WD-37/U cable.
Large ring (8) should be installed with angled portion facing front of connector.
Be sure a sealing grommet is inside middle body (9) before installing.
4. Slide gland retaining nut (2), strain relief axial grip (3), cable sealing gland (4), gland
retaining washer (5), back-end body (6), braid retaining ferrule (7), large ring (8), and
middle body (9) onto cable, and back out of the way.
CAUTION
Be careful not to nick or cut outer copperweld braid.
5. Trim outer cable jacket (10) to 2 3/8 1/32 inches from the cut end of cable.
3-21